ProCurve 6200yl User's Guide Page 497

  • Download
  • Add to my manuals
  • Print
  • Page
    / 596
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 496
13-45
Configuring Port-Based and User-Based Access Control (802.1X)
Configuring Switch Ports To Operate As Supplicants for 802.1X Connections to Other Switches
If, after the supplicant port sends the configured number of start
packets, it does not receive a response, it assumes that switch “B” is
not 802.1X-aware, and transitions to the authenticated state. If switch
“B” is operating properly and is not 802.1X-aware, then the link should
begin functioning normally, but without 802.1X security.
If, after sending one or more start request packets, port A1 receives
a request packet from port B5, then switch “B” is operating as an
802.1X authenticator. The supplicant port then sends a response/ID
packet. If switch “B” is configured for RADIUS authentication, it
forwards this request to a RADIUS server. If switch “B” is configured
for Local 802.1X authentication, the authenticator compares the
switch “A” response to its local username and password.
2. The RADIUS server then responds with an MD5 access challenge that
switch “B” forwards to port A1 on switch “A”.
3. Port A1 replies with an MD5 hash response based on its username and
password or other unique credentials. Switch “B” forwards this response
to the RADIUS server.
4. The RADIUS server then analyzes the response and sends either a “suc-
cess” or “failure” packet back through switch “B” to port A1.
A “success” response unblocks port B5 to normal traffic from port A1.
A “failure” response continues the block on port B5 and causes port
A1 to wait for the “held-time” period before trying again to achieve
authentication through port B5.